Fire Fighting Systems
Advanced Fire Protection Solutions — Comprehensive systems with hydrants, sprinklers, foam systems & clean agents.
Types of Fire Fighting Solutions

Fire Hydrant Systems
Powerful first-response networks for controlling major fires.
- Wet riser, downcomer & yard hydrant networks
- Pump room with main, jockey & standby pumps
- Underground/overhead water tanks as per IS:13039
- Ideal for factories, high-rises, and large campuses
Starting from ₹2,50,000

Automatic Sprinkler Systems
Fully automated suppression systems for immediate response.
- Heat-activated sprinklers discharge water instantly
- Available in wet, dry, and pre-action configurations
- Installed as per IS:15105 / NFPA 13 standards
- Suitable for malls, offices, basements & warehouses
Starting from ₹1,80,000

Hose Reel Systems
Compact and easy-to-deploy manual firefighting units.
- Continuous water supply through semi-rigid hoses
- Designed for quick activation by trained occupants
- Can be integrated with fire hydrant systems
- Wall-mounted or cabinet-mounted models available
Starting from ₹25,000

Foam-Based Systems
Effective for flammable liquids and chemical fires.
- Uses AFFF / AR-AFFF / Protein foam concentrates
- Works on Class B hydrocarbon and solvent fires
- Fixed foam chambers, monitors & proportioners
- Commonly used in refineries, airports & fuel stations
Starting from ₹3,50,000

CO₂ & Clean Agent Systems
Residue-free suppression systems for sensitive environments.
- Quick discharge using CO₂, FM200, or NOVEC 1230
- Suitable for data centers, control rooms & server racks
- Zero damage to electronics & minimal downtime
- Available in total flooding or local application types
Starting from ₹4,50,000

Portable Fire Extinguishers
Essential frontline tools for small or localized fires.
- Available in ABC, CO₂, Foam, Water & Clean Agent types
- ISI-marked & pressure-tested for reliability
- Lightweight, wall-mounted & easy to use
- First response before system activation
Starting from ₹800
Key Features of Fire Fighting Systems
Automatic Detection & Activation
Integrated with sensors, alarms & control panels for rapid response.
- Integrated with sensors, alarms & control panels
- Rapid response to temperature or smoke rise
- Ensures round-the-clock protection
- Automated activation systems
Comprehensive System Design
Customized hydraulic and flow design as per site requirements.
- Customized hydraulic and flow design per site layout
- Pressure calculation as per pump capacity and floor height
- Adheres to NBC, IS & NFPA standards
- Professional engineering design
UL/FM Certified Components
Superior quality pipes, valves & pumps for long-lasting reliability.
- Superior quality pipes, valves & pumps for reliability
- Corrosion-resistant materials for longer life
- Globally certified for safety & performance
- International quality standards
System Integration & Monitoring
Seamless integration with Fire Alarm, PA & BMS systems.
- Seamless integration with Fire Alarm, PA & BMS systems
- Real-time monitoring via control room interface
- Automatic pump start with pressure switch activation
- Centralized control systems
Ease of Maintenance
Simple inspection and minimal recurring maintenance costs.
- Isolating valves and drain systems for quick inspection
- Easy pressure testing and refilling access
- Minimal recurring maintenance cost
- User-friendly maintenance protocols
Regulatory Compliance & Safety
Meets all local fire department and NBC approval norms.
- Meets local fire department and NBC approval norms
- Design & commissioning by certified professionals
- Fire NOC ready documentation & testing
- Full compliance certification
Key Components of Fire Fighting Systems
Fire Pumps
The heart of every firefighting system maintaining constant pressure.
- Main, Jockey & Diesel-driven pumps maintain constant pressure
- Horizontal split case or end-suction types
- Automatically activated via pressure switch
- Designed per IS:12469 & NFPA 20
Piping Network
Ensures efficient water distribution throughout the premises.
- Uses Class B or C MS/GI pipes as per IS:1239 / IS:3589
- Pressure-rated fittings for long-term safety
- Painted red with directional flow markings
- Designed to withstand up to 16 kg/cm² pressure
Hydrants & Landing Valves
Frontline discharge points for manual firefighting operations.
- Single/double outlet landing valves with instantaneous couplings
- Hose boxes equipped with canvas hoses & branch pipes
- Installed at staircases, corridors & outdoor areas
- Made of gunmetal/brass to resist corrosion
Sprinkler Heads
Automatic water discharge units triggered by heat detection.
- Available in pendent, upright, sidewall, and concealed types
- Temperature-rated bulbs (68°C–141°C)
- Chrome, brass, or white finish based on interior design
- Designed per NFPA 13 for coverage & flow rate
Control & Monitoring Panel
Centralized electrical control system for pump operations.
- Auto/manual operation mode
- Displays pump status, power supply & alarms
- Includes emergency stop, pressure indicators & overload protection
- Real-time monitoring capabilities
Water Storage Tanks
Dedicated source of firefighting water with adequate capacity.
- Overhead and underground reservoirs as per IS:3370
- Capacity based on hazard classification & area size
- Equipped with float valves and level indicators
- Separate suction and delivery connections
Ready to Protect Your Facility?
Contact us today for a free consultation and site assessment.